Urri
Member
Posts: 11
Joined: 21 May 2008 10:24

OXE remote maintance

Post by Urri »

I have troubles with OXE (crystal) remote maintance with internal RMA mosem. Single CPU without RMA board. I try to connect modem to A and B ports on RMA box, but have no success. Modem connects successfully, but I receive no responce from PBX.
What is the problem? Modem setup or CPU port?
knightr1der

Re: OXE remote maintance

Post by knightr1der »

what happens when you connect directly to posts A or B? everything ok?

What happens when you connect modem to laptop (instead of OXE). Running terminal or other terminal emulator program, can someone dial in and have a chat?

If both of those are ok - there is problem with cable between modem & OXE maybe!
Urri
Member
Posts: 11
Joined: 21 May 2008 10:24

Re: OXE remote maintance

Post by Urri »

Both ports on OXE are functunal. Modem also is OK. I use the cable supplied with modem and DB9-DB25 convertor. I don't understand anything. :?
knightr1der

Re: OXE remote maintance

Post by knightr1der »

Urri wrote: I don't understand anything. :?
OK Urri - don;t punish yourself just yet... :lol:

For the hell of it, can you try a null adaptor between the modem and the OXE port?
Urri
Member
Posts: 11
Joined: 21 May 2008 10:24

Re: OXE remote maintance

Post by Urri »

Of course! But have the same result!
Tomorrow will try again.
User avatar
cavagnaro
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 7013
Joined: 14 Sep 2005 19:45
Location: Brasil, Porto Alegre
Contact:

Re: OXE remote maintance

Post by cavagnaro »

I did once have a similar issue and was that the modem somehow got desconfigured, an OXE guy connected to it and put many AT commands and worked...for a month when it died completely :?
Ignorance is not the problem, the problem is the one who doesn't want to learn

OTUC/ICS ACFE/ACSE R3.0/4.0/5.0/6.0
Certified Genesys CIV 8.5
Certified Genesys Troubleshooting 8.5
Certified Genesys BEP 8.x
Genesys Developer
Urri
Member
Posts: 11
Joined: 21 May 2008 10:24

Re: OXE remote maintance

Post by Urri »

Surprise! :D
After the restart of CPU modem is working properly. Thanks ALL!
knightr1der

Re: OXE remote maintance

Post by knightr1der »

Urri wrote:Surprise! :D
After the restart of CPU modem is working properly. Thanks ALL!
Thanks for keeping us updated Urri. However, this is not a surprise for us. Your action is the unofficial fix given for a great many number of problems on the OXE. That one task clears more problems than any other possible solutions for any other problems :?
doublevand981
Member
Posts: 246
Joined: 09 Apr 2009 21:38
Contact:

Re: OXE remote maintance

Post by doublevand981 »

knightr1der wrote:
Urri wrote:Surprise! :D
After the restart of CPU modem is working properly. Thanks ALL!
Thanks for keeping us updated Urri. However, this is not a surprise for us. Your action is the unofficial fix given for a great many number of problems on the OXE. That one task clears more problems than any other possible solutions for any other problems :?
Hi all,

i got problem with this case

- i connected directly ExA, SysA... ports on RMA card , OK
- directly modem , OK. at command with Ok response

- when i dial-up from remote site to modem . AT command with OK, ATD command OK. but i can not acess RMA login.

any one can help me ??


thanks so much
Gedeon

Re: OXE remote maintance

Post by Gedeon »

Be carefull for modem directly connected on CPU port (console port).
You MUST configure the modem to NOT reply for any message from the port.
In other case you can stop the reboot of your CPU (100% this CPU5/6, many risk with CPU7) but the modem return ENTER with ERROR message... and the CPU can stop the boot and display the bios configuration...

Don't forget to save the configuration in the register.

G.