Analog Extension problem

Aamir-KHI

Analog Extension problem

Post by Aamir-KHI »

Hi all,

In OXO, I have a problem with analog extensions. When I put my receiver back to phone after talking on a trunk line, I get some callback sort of ring on my phone. But when I listen it on receiver, nobody is there. Any solution ??

Bunch of Thanks,
Aamir.
Last edited by Aamir-KHI on 21 Nov 2007 23:22, edited 1 time in total.
Aamir-KHI

Post by Aamir-KHI »

Nobody to answer ???????
:?
User avatar
cavagnaro
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 7013
Joined: 14 Sep 2005 19:45
Location: Brasil, Porto Alegre
Contact:

Re: Analog Extension problem

Post by cavagnaro »

Usually that happens when on the other side line is open, you get a ringback. Check your trunks
Ignorance is not the problem, the problem is the one who doesn't want to learn

OTUC/ICS ACFE/ACSE R3.0/4.0/5.0/6.0
Certified Genesys CIV 8.5
Certified Genesys Troubleshooting 8.5
Certified Genesys BEP 8.x
Genesys Developer
Jigger

Re: Analog Extension problem

Post by Jigger »

check under its feature's, master mailing is prolly ticked?? untick that and give it a go....

ive never had the issue but ive had people mention to me that seems to be the cause?
hung.le

Re: Analog Extension problem

Post by hung.le »

I have the same problem, but still don't have solution for it.
Oxosaysno

Re: Analog Extension problem

Post by Oxosaysno »

I kinda had this problem once before. however it was analogue and digital phones all affected and it was due to the disconnect timers on the analogue trunks. what type of lines are being used?
hung.le

Re: Analog Extension problem

Post by hung.le »

I am using Analog trunks.
jopatini

Re: Analog Extension problem

Post by jopatini »

hung.le wrote:I am using Analog trunks.
I had the same problem in OXE R7.0. The sulution in this case is the followng:

For the involved SLI:
Shelf - Board - SLI position
Send Init Dynamic Msg = TRUE
Param By Default = FALSE

In the go down menu - Dynamic Init Parameter set following parameter:
P20 = 2
P21 = 0
P22 = 15
P23 = 0
P24 = 2
P25 = 0
P26 =22
P27 = 1

Please RESET the coupler SLI after the above modification.
User avatar
cavagnaro
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 7013
Joined: 14 Sep 2005 19:45
Location: Brasil, Porto Alegre
Contact:

Re: Analog Extension problem

Post by cavagnaro »

This is an OXO issue, not an OXE.
Ignorance is not the problem, the problem is the one who doesn't want to learn

OTUC/ICS ACFE/ACSE R3.0/4.0/5.0/6.0
Certified Genesys CIV 8.5
Certified Genesys Troubleshooting 8.5
Certified Genesys BEP 8.x
Genesys Developer
User avatar
tot3nkopf
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 4058
Joined: 02 Feb 2006 10:41
Location: Germany & Romania
Contact:

Re: Analog Extension problem

Post by tot3nkopf »

He may do the same but on noteworthy addresses.
Post Reply

Return to “Configuration”