IBS Handover MG
IBS Handover MG
Is it possible to have handover with IBS from MG to other MG?
I have 3 MG with IBS. MG connected via fiber LAN.
OXE is R11 only with IBS Stations.
I have 3 MG with IBS. MG connected via fiber LAN.
OXE is R11 only with IBS Stations.
Re: IBS Handover MG
No handover between IBS's connected to different MG's possible. It was discussed before but I couldn't find this thread.
Handover only works between:
- ACT's connected via INTOF
- MG's connected via HSL (Main and peripheral shelves).
Handover only works between:
- ACT's connected via INTOF
- MG's connected via HSL (Main and peripheral shelves).
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
Re: IBS Handover MG
Thanks Alex. I thought with R11 it would be possible. 

Re: IBS Handover MG
Roaming must be possible, right? Do I need Licence for Roaming?
I have ACTIS. Example with 50 Mobiles. Actually i have:
Central Area: 50 DECT User. 0 for outgoing Roaming.
MG: DECT 5 user. 0 incoming Roaming.
Must i have in MG also 50 DECT? Do I need outgoing/incoming Roaming license?
I have ACTIS. Example with 50 Mobiles. Actually i have:
Central Area: 50 DECT User. 0 for outgoing Roaming.
MG: DECT 5 user. 0 incoming Roaming.
Must i have in MG also 50 DECT? Do I need outgoing/incoming Roaming license?
Re: IBS Handover MG
In OXE you use "roaming" in a networked context, i.e. if you have an ABC-network and DECT users on all nodes.
If you have only one PABX then there is no need for "roaming" licensies.
But there are some restrictions with IBSes connected to fifferent MG's. Check this thread "System not available on DECT 400"
If you have only one PABX then there is no need for "roaming" licensies.
But there are some restrictions with IBSes connected to fifferent MG's. Check this thread "System not available on DECT 400"
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
Re: IBS Handover MG
Thanks again Alex. Now I am understanding.
I think i have problem with overlapping. Now I will check if i can connect all IBSfrom MG to the Central Gateway.
I hope theres a cable between buildings. If not I have no chance or did you have an idea to solve this?
I think i have problem with overlapping. Now I will check if i can connect all IBSfrom MG to the Central Gateway.
I hope theres a cable between buildings. If not I have no chance or did you have an idea to solve this?
Re: IBS Handover MG
That's the only solution if you have overlapping coverage of IBS's connected to different MGs.Maulwurf wrote:... if i can connect all IBSfrom MG to the Central Gateway.
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
- MTConsulting
- Member
- Posts: 122
- Joined: 01 Feb 2010 04:21
- Location: Sydney - Innerwest
Re: IBS Handover MG
IBS will work across at least 2klm of copper twisted pair cable, you can also locally power the IBS Base Stations if they are a very long way away from the main GD.Maulwurf wrote:Thanks again Alex. Now I am understanding.
I think i have problem with overlapping. Now I will check if i can connect all IBSfrom MG to the Central Gateway.
I hope theres a cable between buildings. If not I have no chance or did you have an idea to solve this?
Re: IBS Handover MG
really 2 kilometers? i thought it was max. 700 meters for UA Links.
regards...
regards...
--- back to basics... focus your eyes to the essential things... ---
- MTConsulting
- Member
- Posts: 122
- Joined: 01 Feb 2010 04:21
- Location: Sydney - Innerwest
Re: IBS Handover MG
You thought wrong.