Hi all,
I have a oxo Rel 6.1 system in which two PRI Lines are connected of two different service providers.
I have terminated both lines in the system and configured for DID/DOD.
At a time only one PRI's DOD works(but both DID work),
I have checked it in DID modifiction table, also in Numbering plan.
Regards,
SS
DID/DOD configuration
Not guru in OXO but main idea.
I think you have problem with calling number - in classic way (installation + DID number) you can create right calling number only for one provider. For next one you need to manage Alternative CLIP.
Manage Alternative CLIP in user parameters, manage outgoing call via ARS and for second provider (in ARS mark Opt. parameters) play with calling number (pub./ priv).
I think you have problem with calling number - in classic way (installation + DID number) you can create right calling number only for one provider. For next one you need to manage Alternative CLIP.
Manage Alternative CLIP in user parameters, manage outgoing call via ARS and for second provider (in ARS mark Opt. parameters) play with calling number (pub./ priv).
Hi,
another idea is not to use DDI modification table if possible, it's what I try to do most time to avoid problems.
if you remove all common starting digit from both operator numbers (city code, etc...) and if the result is less or equal 8 digits, use these digits in the public numbering plan (means no installation has to be filled out)
provider 1: 0123456-100 to 0123456-120
provider 2: 0123789-200 to 0123798-220
see pictures for configuration.
Regards,
Maurice
another idea is not to use DDI modification table if possible, it's what I try to do most time to avoid problems.
if you remove all common starting digit from both operator numbers (city code, etc...) and if the result is less or equal 8 digits, use these digits in the public numbering plan (means no installation has to be filled out)
provider 1: 0123456-100 to 0123456-120
provider 2: 0123789-200 to 0123798-220
see pictures for configuration.
Regards,
Maurice
You do not have the required permissions to view the files attached to this post.
Hi, Not sure of the network setup in your country but in mine if both PRA are supplied by the same provider they must enable features to allow all DDIs to be presented in (series completion) and out (series association) over both PRA. If provided by seperate suppliers then we use ARS to force the extn to call out on the PRA that has their DDI.
Best Regards
Murray
ACSE 10.0 corporate
ACSE 6.x IPT data
Murray
ACSE 10.0 corporate
ACSE 6.x IPT data
- MTConsulting
- Member
- Posts: 122
- Joined: 01 Feb 2010 04:21
- Location: Sydney - Innerwest
Re: DID/DOD configuration
this we have done recentlybaban_ele wrote:Hi all,
I have a oxo Rel 6.1 system in which two PRI Lines are connected of two different service providers.
I have terminated both lines in the system and configured for DID/DOD.
At a time only one PRI's DOD works(but both DID work),
I have checked it in DID modifiction table, also in Numbering plan.
Regards,
SS
DP