SMDR Data collection OXO

Post Reply
DFK

SMDR Data collection OXO

Post by DFK »

Hi I need to collect SMDR/CDR (Calls raw data) from OXO rls 7. I could not found a way of doing that and tried document but still no success the way to collect raw data of all outgoin calls?? can somebody guide me the menu options/or conmfiguration ?? how can i setup a PC to collect outgoing calls raw data.
thanks
etc

Post by etc »

There are exist two ways of doing that.
First: doesn't require license, but require additional hardware: 4083 ASM or 4093 module - serial port to UA converter. COM-port of PC connect to this module, choose this module in OMC/ Metering/ Metering Transmission Characteristics and activate metering: OMC/ Metering/ Metering/ External Metering Activation V24.
Second: require license "Call accounting over IP" and software "Office Link Driver" (OLD).
This is all written in documentation part 8.4 Call Metering.
bkct11
Member
Posts: 7
Joined: 28 Oct 2008 08:34

Post by bkct11 »

I have a problem with creat V24 access.
- i change "Terminal/base stat" of UA Port to TA
- After that i try to creat V24 access but when i select UA port and click Add, the "Sub device" is inselectable --> can not creat V24 access

anyone had problem before? If had, pls share your experience.

thanks!
etc

Post by etc »

You don't need to create this. Simply connect TA to OXO, after that - refresh Subscriber/Basestation List. There are you wiil see your TA and V24 subdevice.
elkiwi

Post by elkiwi »

In case that don't work disconnect TA, configure that port like UA Access and then reconect TA. That must works.
Post Reply