Dialing Lists? Viewing and printing possible?

mozi

Post by mozi »

If you want to solve your problem with a serial printer or a PC wich collects the datas at com1 / com 2 there is one possibility:
You have to install a TA 4093 / v24.

This TA you can only install as a stand alone Ta or behind the old Reflexes or the first UA Generation. After you installed the 4093 you have to confige this TA as the : selected metering interface. ( Metering -> Metering Transmisson Characteristic )

( If there is only one Ta 4093, this one is automtically selected.)

Now you can enable external metering acticvation.
To get incomming calls there is a listbox in:

subscriber-> extentins nbr.-> details-> metering-> Monitoring
kaype_DUP

Post by kaype_DUP »

Hi :)

thanks for the answers :)

This forum is absolutly great :D

i actualy bought a used 4093 V.24 Plugware für 21 bugs ... :roll:

my further plan is:

setting up the 4093 as a TA Device, it is the only 4093 in the system, i got 5 other 4094 TAs in my system, should there anything configured to work probably?

I connect the 4093 to the comport of my server or any other Computer

now i need a software that read the "V.24 feed" from the com-port an paste it in a file located on my network-drive ... then my problem should be solved.

is there any software wich can solve this little job unproblematic?

sorry for my cheap english, ... Fabian ...
kaype_DUP

Post by kaype_DUP »

Yeah ... works fine!

i plugged the 4093 V.24 into an UA Port, set it up for metering and read everything via Comport with an terminalprogram and paste it into an txt File wich is public in the intranet ... perfect ... thanks everyone for helping me out on this problem!

greetings, Fabian
Post Reply