Hi guys,
I'm checking all my Outbound installations due to a problem i'm having on a customer.
I need better explanation or examples on how this timers work:
For VAD
314
315
For No Answer Detection Time:
267
268
I have read all documents available an can't understand them. Maybe if somebody has a diagram or flow where this timers apply will be great.
Thanks a lot
Outbound timers
-
knightr1der
Re: Outbound timers
267
T_WAIT_DTO_UNI
Max wait during the activation of the DTO_Universal
268
T_WAIT_DTO_VAD
Max wait during the activation of the DTO_VAD
OK, this is an outbound solution, correct?
What exactly is the problem on the sys?
I have an outbound trouble shooting doc that might help. come back to me. MSN if you can
T_WAIT_DTO_UNI
Max wait during the activation of the DTO_Universal
268
T_WAIT_DTO_VAD
Max wait during the activation of the DTO_VAD
OK, this is an outbound solution, correct?
What exactly is the problem on the sys?
I have an outbound trouble shooting doc that might help. come back to me. MSN if you can
Re: Outbound timers
I use the following timers
For VAD
314 = (6 to 12) "Alo"
315 = (2 to 5) "silence" after Alo
For No Answer Detection Time:
267 = 100 (10 seconds to detect busy tone)
268 = 350 (35 seconds "about 9 rings" to detect voice activity and ring back tone to mark the call as not answer)
For VAD
314 = (6 to 12) "Alo"
315 = (2 to 5) "silence" after Alo
For No Answer Detection Time:
267 = 100 (10 seconds to detect busy tone)
268 = 350 (35 seconds "about 9 rings" to detect voice activity and ring back tone to mark the call as not answer)
--
finaluser
finaluser