How to clear status change

Post Reply
itayal

How to clear status change

Post by itayal »

Hi,

I would like to know if is possible to clear status change when I do « show interface » for reset counter.

Many thanks,

Itayal
User avatar
Gleylancer
Member
Posts: 164
Joined: 08 May 2013 03:14

Re: How to clear status change

Post by Gleylancer »

AOS6:
interface x/xx no l2 statistics

AOS8:
clear interface x/xx l2-statistics
itayal

Re: How to clear status change

Post by itayal »

Hello Gleylancer,

Thanks for reply.
Unfortunately, this command clear all statistics except the line « Number of Status Change : x » :(
silvio
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 2094
Joined: 01 Jul 2008 10:51
Location: Germany

Re: How to clear status change

Post by silvio »

in my opinion there is no way to clear the count of status changes .... beside reboot of the switch.
best regards
Silvio
User avatar
Gleylancer
Member
Posts: 164
Joined: 08 May 2013 03:14

Re: How to clear status change

Post by Gleylancer »

Same here, I do not know of any other way to set the status changes to zero, it's a value not covered by l2-statistics, which makes sense, since such a status change is layer 1.
Post Reply

Return to “OmniSwitch 6860 / 6860E”