To forbid routing you need only to configure the rules at the router.
But I prefer to configure the rules at the edge too. For this you can use OV (f.e. with cli scripts) to configure all access switches in one step.
Search found 1890 matches
- 16 May 2024 02:13
- Forum: OmniSwitch 6900
- Topic: VLAN isolation
- Replies: 3
- Views: 90
- 16 May 2024 02:10
- Forum: OmniSwitch 6900
- Topic: Virtual-Chassis of OS6900-X40 & OS6900-X48
- Replies: 3
- Views: 82
Re: Virtual-Chassis of OS6900-X40 & OS6900-X48
correct. The old hardware (X20/40, T20/40, X72/Q32) can be connected in one VC up to 6. And all new switches too (X24/48, T24/48, V72, C32). But the old switches and the new one can not connected together in one VC.
BR Silvio
BR Silvio
- 14 May 2024 13:37
- Forum: OmniSwitch 6900
- Topic: VLAN isolation
- Replies: 3
- Views: 90
Re: VLAN isolation
You need routing and you need policies. The policies you should configure at your router=gateway (switch or firewall).
For you private-vlan is not a solution. You need ACL/policies.
BR Silvio
For you private-vlan is not a solution. You need ACL/policies.
BR Silvio
- 03 May 2024 12:12
- Forum: OmniSwitch 6900
- Topic: CLI Message
- Replies: 2
- Views: 317
Re: CLI Message
difficult to understand this. For real clearance you need to open a ticket (maybe you find something in the knowledgebase in myportal). - svc means service (used for SPB or VxLAN). - 1010 means port 1/1/1 - accessport is an unp port type access - info -> this isn't a problem maybe a misconfiguration
- 28 Apr 2024 12:08
- Forum: OmniSwitch 2260 / 2360
- Topic: oversize frames on fiber port
- Replies: 2
- Views: 204
Re: oversize frames on fiber port
I am wondering about the same value for RX Oversize and CRC at all the ports. I assume the oversize is an display issue - you need to check with ALE support (but only with actal AOS release). CRC is mostly bad fibre connection (dirty connectors etc.). Use other connections/patchcables (if possible)....
- 28 Apr 2024 11:56
- Forum: OmniSwitch 9900
- Topic: Reload Working configuration without reboot
- Replies: 3
- Views: 255
Re: Reload Working configuration without reboot
maybe the syntax is not fully correct (not checked it). Use the tab-key to find out the correct syntax.
- 25 Apr 2024 14:47
- Forum: OmniSwitch 9000 / 9000E
- Topic: static route from source IP to destination
- Replies: 2
- Views: 216
Re: static route from source IP to destination
This is possible (named PBR - policy based routing). Search in the guides (or here in the forum) for "policy action permanent-gateway".
BR Silvio
BR Silvio
- 25 Apr 2024 14:45
- Forum: OmniSwitch 6860 / 6860E
- Topic: Disable TCP services on switch
- Replies: 3
- Views: 510
Re: Disable TCP services on switch
I know only the predifined services like telnet, ssh...
Search in cli-guide or open a ticket.
BR Silvio
Search in cli-guide or open a ticket.
BR Silvio
- 25 Apr 2024 14:43
- Forum: OmniSwitch 6850 / 6850E
- Topic: Can I use 510W power for a 6850E(non-poe switch)
- Replies: 1
- Views: 154
Re: Can I use 510W power for a 6850E(non-poe switch)
Try it. It should work
- 25 Apr 2024 14:42
- Forum: OmniSwitch 9900
- Topic: Reload Working configuration without reboot
- Replies: 3
- Views: 255
Re: Reload Working configuration without reboot
copy certified working make-running-directory