Sorry for the late reply but I've been busy with other projects so I put it aside.
Deleting the user table with the highest number worked!
Thank you for your help!
Search found 5 matches
- 08 Aug 2023 11:46
- Forum: OmniSwitch 6350
- Topic: No login prompt via serial console
- Replies: 9
- Views: 24221
- 22 Mar 2023 08:12
- Forum: OmniSwitch 6350
- Topic: No login prompt via serial console
- Replies: 9
- Views: 24221
Re: No login prompt via serial console
I'm still struggling. I'd appreciate your help!
- 14 Mar 2023 14:24
- Forum: OmniSwitch 6350
- Topic: No login prompt via serial console
- Replies: 9
- Views: 24221
Re: No login prompt via serial console
Thank you for your tips! I've managed to communicate via serial in putty with baudrate 9600. I had to change some settings in the Windows device manager for my serial adapter: baudrate 9600 data bits 8 parity none stop bits 1 flow control xon/xoff flow control was set to none before. When I changed ...
- 03 Mar 2023 14:57
- Forum: OmniSwitch 6350
- Topic: No login prompt via serial console
- Replies: 9
- Views: 24221
Re: No login prompt via serial console
I've already tried pressing enter, typing admin but it doesn't react at all.
Should I reset the switch again? It should be possible via Miniboot, right?
I'm using putty at baudrate 9600 btw.
Should I reset the switch again? It should be possible via Miniboot, right?
I'm using putty at baudrate 9600 btw.
- 28 Feb 2023 14:09
- Forum: OmniSwitch 6350
- Topic: No login prompt via serial console
- Replies: 9
- Views: 24221
No login prompt via serial console
Greetings, I've bought an used OS6350-P24 and it works out of the box. But if I try to login via serial console to activate a GUI (there is one, right?), I don't get a login prompt, it's just the cursor. If I restart the switch with serial connected I get the following output: ▒ General initializati...