Search found 4 matches

by tomtom76
26 Jan 2024 00:59
Forum: GENERAL
Topic: Bearer Cabability on 4094 S0 via SIP Trunk (OXE)
Replies: 1
Views: 1015

Bearer Cabability on 4094 S0 via SIP Trunk (OXE)

Hi! My Company is running a OXE with BRI Lines (ISDN), latest Software We are runnning a Faxserver on a 4094 S0 Card, which is connected via a ISDN Card. Incoming Faxes via BRI-Trunk (extension 666) are signaled as "3.1 kHz Voice" on the 4094 and our ISDN Fax is receiving them fine. Incomi...
by tomtom76
06 Jul 2015 16:56
Forum: Configuration
Topic: ISDN T0 GSM Gateway Call Dropping
Replies: 0
Views: 2036

ISDN T0 GSM Gateway Call Dropping

We have a Public T0 from our Carrier for incoming Calls, on the 2nd T0 Port we have connected a Kuhnt GSM Gateway. The Gateway is configured to handle all outgoing calls. Very often Calls are Dropped after a few Seconds. It seems a ISDN Sync issue. I alread disabled Clock delivery from this Line. It...
by tomtom76
06 Jul 2015 16:51
Forum: Hardware
Topic: MIX244 Mixed Board Software Version
Replies: 0
Views: 3337

MIX244 Mixed Board Software Version

On Our OXO there are 2 MIXed Boards with different SW-Version.
Does anybody know what are the Differences?


Image
by tomtom76
26 Apr 2009 10:44
Forum: MAIN
Topic: OXO Release 7 with ACD - Calls with none DDI to ACD
Replies: 2
Views: 1716

OXO Release 7 with ACD - Calls with none DDI to ACD

I have the following problem on a OXO Release 7 with ACD.

ACD works on dialing the main number + 10
So 0660 4711-10 and the call is in acd.
Now all calls to 0660 4711 should be directly routed to the ACD and not to the Attendand Group
How could i make this?

thank you very much

Go to advanced search