I have an oxe in R11.1 with an ACD2, the client want two things:
First: They want to the agents, when call to a internal extension, display de number of the pilot, not his agent number. In external calls its posible, but its posible in internal?
Second: They want that direct calls to the pro-acd number were filter and some calls, according to the internal called number not external called number, go to the pilot and other to the agent behind the pro-acd. Its posible?
Regards
Two questions
Re: RE: Two questions
Use a physical ISDN loop.omarsg1977 wrote:I have an oxe in R11.1 with an ACD2, the client want two things:
First: They want to the agents, when call to a internal extension, display de number of the pilot, not his agent number. In external calls its posible, but its posible in internal?
Second: They want that direct calls to the pro-acd number were filter and some calls, according to the internal called number not external called number, go to the pilot and other to the agent behind the pro-acd. Its posible?
Regards
With it should solve both issues
Enviado do meu ALE-L21 através de Tapatalk
-
- Member
- Posts: 30
- Joined: 28 Jan 2016 08:00
Re: Two questions
Do you have some documentation about it? I never do this config.
Regards.
Regards.
- cavagnaro
- Alcatel Unleashed Certified Guru
- Posts: 7013
- Joined: 14 Sep 2005 19:45
- Location: Brasil, Porto Alegre
- Contact:
Re: Two questions
Just take two Pra boards, connect them with a cable, one in TX and other for Rx, as master/slave then create on oxe a prefix to use that trunk so the call returns to oxe as external, the NPD of this trunk sends to anywhere you want but as external call.
Enviado de meu C6603 usando Tapatalk
Enviado de meu C6603 usando Tapatalk
Ignorance is not the problem, the problem is the one who doesn't want to learn
OTUC/ICS ACFE/ACSE R3.0/4.0/5.0/6.0
Certified Genesys CIV 8.5
Certified Genesys Troubleshooting 8.5
Certified Genesys BEP 8.x
Genesys Developer
OTUC/ICS ACFE/ACSE R3.0/4.0/5.0/6.0
Certified Genesys CIV 8.5
Certified Genesys Troubleshooting 8.5
Certified Genesys BEP 8.x
Genesys Developer