PRI Config problem

Post Reply
baban_ele_DUP

PRI Config problem

Post by baban_ele_DUP »

Hi all,
I have Two PRI from different service providers(suppose A and B)
I have connected both in OXO System (Rel 6.1),
programmed like this:
DID modification table 1 xxxx-41 (A PRI)
2 xxxx-42 (B PRI)
Public No Plan 41500 41699 500 (500 is extn series)
42500 42699 500 ( ,, )

Istallation No. is blank



Now DID/DOD works for only one(for A) PRI. For second PRI (for B) only DID works.

Can be programmed oxo to use the both PRI's DID along with DOD? :?
Friday

Re: PRI Config problem

Post by Friday »

There are two ways to make this work as I can see:
1: Other labels: DDIMnused has to be set to 01 in ordrer to use DDI modification table.
or
2: Try with the full public number in Public Numbering Plan and blank installation number.
Post Reply

Return to “Configuration”