I can't alter "out of service" of a 4034(digital)

Are you having any trouble while you are configuring a 4400 on site ? Share it with us, maybe someone will have the solution !
Post Reply
crustas

I can't alter "out of service" of a 4034(digital)

Post by crustas »

Hello all

I've at my work a A4400.

This week a user, disconnected his digital phone (4034) and tried to connect a analog modem to the plug as result the phone now doesn't work, it's out of service.

I did the "listout set" command, and the equipment appears there with only one out of service flag, 'A', wich means "waiting implementation".

And the flag should be 'A' and 'U'(wich means out of service because cable not connected)

I've tried the following commands and so far nothing
commands:
- reinit
- rstcp
- outserv
- inserv
- termstat + reset device

i've also reboot the machine...


Please help me
Thanks

Crustas
User avatar
frank
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3386
Joined: 06 Jul 2004 00:18
Location: New York
Contact:

Post by frank »

did you try the set on another port ?
did you try another set on the port ?
Code Free Or Die
crustas

Post by crustas »

frank wrote:did you try the set on another port ?
did you try another set on the port ?
Yes, the set is OK.

Someone has told me to delete the directory number and to create it again. I've tried but so far i achieve nothing.

Thanks
Crustas
User avatar
frank
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3386
Joined: 06 Jul 2004 00:18
Location: New York
Contact:

Post by frank »

Did you tried to delete the set on this EXACT port, and recreate another one different ? (Analog, 4020) ?

If it's still doesn't work, then I would say that the port on the board is dead
Code Free Or Die
crustas

Post by crustas »

frank wrote:Did you tried to delete the set on this EXACT port, and recreate another one different ? (Analog, 4020) ?

If it's still doesn't work, then I would say that the port on the board is dead
Yes, i deleted the set on the exact port and recreated another one.

I've talked to Alcatel and i'm waiting for the Alcatel people to assist me. I've start to think that might be software malfunction, because it's very, very old:
Chorus version : v11.7/1.6
Delivery software version : a9.544
Software Version Name : R1.4.1


After i know the answer i will post it here.

Thank for the help

Crustas
IceMan_DUP

Post by IceMan_DUP »

Did you try putting the set on 255,255,255?
then unplug the cable/set and put it back in service?

Maybe you can pull the UA board out and back in or swap with anotherone just to check if the port is really dead.
vad
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3852
Joined: 23 Sep 2004 06:47

Post by vad »

How you can find problem - connect phone to another port - if works - Phone OK.
Plug in this place another UA board - if port works - database OK.
Plug previous board - if port not works - port physicaly not OK.
crustas

Post by crustas »

Sorry for the delay.

It was no software problem, like i tought it was, this time :)

The technician went there and the problem was the port it is physicaly dead.

He swap ports and everything is ok now.

Thanks to everybody for the help.


Crustas
User avatar
frank
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3386
Joined: 06 Jul 2004 00:18
Location: New York
Contact:

Post by frank »

Yeah, this was my last previous answer, lol
Code Free Or Die
Post Reply

Return to “ON SITE TROUBLES”