Oke. I found this problem yesterday, when my SAM generate some error at my iom3-xp card. The card reboot suddenly. There is information about the card
Code: Select all
===============================================================================
Card 1
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 iom3-xp up up
IOM Card Specific Data
Capabilities : ESS
Clock source : none
Named Pool Mode : Disabled
Fail On Error : Disabled
Available MDA slots : 2
Installed MDAs : 1
FP 1 Specific Data
WRED Admin State : Out Of Service
WRED buffer-allocation max : 2500
WRED buffer-allocation min : 2500
WRED reserved-cbs max : 2500
WRED reserved-cbs min : 2500
WRED Slope Policy : default
hi-bw-mc-srcEgress Alarm : 2
hi-bw-mc-srcEgress Group : 0
mc-path-mgmt Admin State : Out Of Service
Ingress Bandwidth Policy : default
Stable Pool Sizing : False
Hardware Data
Platform type : 7450
Part number : 3HE03620AAAP01
CLEI code : IPU3ADAEAA
Serial number : NS1407F0683
Manufacture date : 02122014
Manufacturing deviations : (Not Specified)
Manufacturing assembly number : 82-0107-13
Administrative state : up
Operational state : up
Temperature : 52C
Temperature threshold : 75C
Software boot (rom) version : X-11.0.R4 on Tue Jul 23 12:27:33 PDT 2013
by builder
Software version : TiMOS-I-11.0.R6 iom/hops ALCATEL ESS 7450
Copyright (c) 2000-2013 Alcatel-Lucent.
All rights reserved. All use subject to
applicable license agreements.
Built on Tue Nov 19 15:14:12 PST 2013 by
builder in /rel11.0/b1/R6/panos/main
Time of last boot : 2014/08/08 15:12:07
Current alarm state : alarm cleared
Base MAC address : 00:d0:f6:f1:00:32
Last bootup reason : runtime failure
Memory capacity : 2,048 MB
When I see last bootup reason from the card, I found the card reboot because runtime failure, I want to ask why runtime failure can be happened?
The I try to looking for alarm generate on Log ID 99. then I found this.
Code: Select all
2893 2014/08/08 15:10:31.46 WIB MAJOR: CHASSIS #2003 Base Card 1
"Class IO Module : removed"
2892 2014/08/08 15:10:31.47 WIB MAJOR: CHASSIS #2016 Base Equipment
"Clear IO Module 1 failure"
2891 2014/08/08 15:10:30.27 WIB MAJOR: CHASSIS #2003 Base Mda 1/1
"Class MDA Module : removed"
2890 2014/08/08 15:10:30.26 WIB MAJOR: CHASSIS #2001 Base Card 1
"Class IO Module : failed, reason: Reported internal hw error"
Thanks so much