Search found 4 matches

by MoniThor
03 Jun 2022 06:07
Forum: Configuration
Topic: ALE-30h has a strong echo during analog trunk conversation
Replies: 2
Views: 2906

Re: ALE-30h has a strong echo during analog trunk conversation

Solved:
Upgraded OXO to the latest release and downloaded phones firmware via Terminals Downloading. All phones work fine now.
by MoniThor
11 May 2022 05:04
Forum: Configuration
Topic: ALE-30h has a strong echo during analog trunk conversation
Replies: 2
Views: 2906

ALE-30h has a strong echo during analog trunk conversation

Hi all, a couple of digital ALE-30h on TDM all have a strong echo during analog trunk conversation. Tried modifying the analog trunk transmission plan in "short line 04/05/06 mm" and this kinda remediates the echo, but it is still strong. Also modified GainUA_TAB, for decreasing gain, but ...
by MoniThor
10 Jun 2016 06:12
Forum: Hotel mode
Topic: OXO integration with Micros Fidelio Suite8
Replies: 14
Views: 24791

Re: OXO integration with Micros Fidelio Suite8

Excerpt from TC0091- Ed 05 Aug 2015:

"The OLD is not to be installed on any Fidelio PC (nor if PC or Fidelio Server) and will not be installed by a
Micros Fidelio resource, but only by an Alcatel-Lucent or dealer resource."
by MoniThor
16 May 2016 04:04
Forum: OmniSwitch 6450
Topic: OS6450-10 does not boot at all
Replies: 5
Views: 5441

Re: OS6450-10 does not boot at all

If you tested your console cable in another Alcatel switch i'd RMA the device. if there is just power and a port LED (unconnected?) on something is very wrong. I'd bet a recovery by USB will not work, as you need uboot/miniboot (and that give some console output) for that. Hello, I have the same si...