by zetor2000
12 Oct 2023 02:23
Forum: VMWARE
Topic: Full Ip abc network with 3 nodes
Replies: 3
Views: 2708

Re: Full Ip abc network with 3 nodes

In a home lab environment i suppose you neeed some extra hw stuff like common hw or WM cabinets, or voice hubs or similar thing you can put interface cards. We used to make connections via LIOB boards, and BRA cards, but there was a limitation in the number of available channels. In a home lab, you ...
by zetor2000
30 Mar 2023 04:57
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 1620

Re: PCS does not work

Hi, From the oxe do a copy of a database backup to the pcs using the following command rcp /DHS3dyn/BACKUP/IMMED/mao swinst@pcs_ip_addr:/DHS3dyn/BACKUP/IMMED Note: replace pcs_ip_addr with the ip address of the pcs After coping the database, compare the file on the CS and on the PCS, to see if they...
by zetor2000
28 Mar 2023 01:57
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 1620

Re: PCS does not work

I did it several times, nothing new happened.
by zetor2000
23 Mar 2023 10:29
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 1620

Re: PCS does not work

I tried pcscopy several times. There was time, when the telephone was started, and there was time when telephone was not started.
The symptom is the same.
by zetor2000
22 Mar 2023 08:52
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 1620

PCS does not work

Hi! I have a site with PCS which does not work properly. The PCS is a CS2 board. The software version is R100.1 n2.514-30, the same running in the call server. I used netadmin -m to configure the PCS, it seems OK, there are hosts file entries, and i can use ping, telnet, ftp to or from the PCS. I se...
by zetor2000
31 Jul 2020 11:22
Forum: OmniVista 8770
Topic: Buffer overflow
Replies: 3
Views: 4103

Re: Buffer overflow

But we do not have real-time accounting enabled.
The PBX just drop some error messages, that appears several hours, 6 times. It is strange.
by zetor2000
24 Jul 2020 05:34
Forum: OmniVista 8770
Topic: Buffer overflow
Replies: 3
Views: 4103

Buffer overflow

Hi! Recently we moved to R12, and we have a new 8770 with accounting. Now i get some errors like: "ACCOUNTING: appli ACC_ETH feature incident 2 3" (information 275) I looked after in incinfo, and it tells me this is a buffer overflow error, the capacity of the internal accounting buffer is...
by zetor2000
29 May 2019 15:41
Forum: Beginner's questions about the Crystal Hardware
Topic: PSAL wiring guide
Replies: 3
Views: 4895

Re: PSAL wiring guide

Thank you, Vad!
I suppose the label shows 48V / 0V / PSAL, the polarity of the 48V is unknowwn. I do not remember. I have to check it, if i get back to my site. :)
I can only remember, if i made a wrong connection, my power sdupply's circuit breaker was shut down the power.
by zetor2000
15 May 2019 09:05
Forum: Beginner's questions about the Crystal Hardware
Topic: PSAL wiring guide
Replies: 3
Views: 4895

PSAL wiring guide

Hi! I received a rather old shelf. It has 10 card spaces. It has a metal box with 3 connectors on the back, 2 of them are +48V and 0V, and the third is labelled "PSAL". I connected the +48V and 0V to a UPS, and the CPU board attached to the cabinet shows signs of life thru a serial console...
by zetor2000
05 Feb 2019 07:34
Forum: Voicemail (46x5)
Topic: SPA3 - what is it for?
Replies: 4
Views: 4901

Re: SPA3 - what is it for?

Thank you!

Go to advanced search