Search found 42 matches

by zetor2000
18 Jul 2024 09:01
Forum: OmniVista 8770
Topic: license file on another server
Replies: 6
Views: 5613

Re: license file on another server


only one instance should running as stated ; shutdown one of them and perform a global synch and all will be back to normal in the next check


Thanks!

I am in a relatively new virtual environment, with several VMs, and there are 2 VMs which we use regularly. One is a file sharing machine, and ...
by zetor2000
18 Jul 2024 02:07
Forum: OmniVista 8770
Topic: license file on another server
Replies: 6
Views: 5613

Re: license file on another server

Hi!
I have the same issue. My server is about to stop in 8 days.
https://i.kek.sh/sNq1vBtYhTm.png

I found the issue when i get back from vacation, and there were 11 days. I had another 8770 server instances on another machines, but i think there is only one instance running, but this server is ...
by zetor2000
12 Oct 2023 02:23
Forum: Other
Topic: Full Ip abc network with 3 nodes
Replies: 3
Views: 4679

Re: Full Ip abc network with 3 nodes

In a home lab environment i suppose you neeed some extra hw stuff like common hw or WM cabinets, or voice hubs or similar thing you can put interface cards.
We used to make connections via LIOB boards, and BRA cards, but there was a limitation in the number of available channels.
In a home lab, you ...
by zetor2000
30 Mar 2023 04:57
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 4187

Re: PCS does not work


Hi,
From the oxe do a copy of a database backup to the pcs using the following command
rcp /DHS3dyn/BACKUP/IMMED/mao swinst@pcs_ip_addr:/DHS3dyn/BACKUP/IMMED
Note: replace pcs_ip_addr with the ip address of the pcs

After coping the database, compare the file on the CS and on the PCS, to see if ...
by zetor2000
28 Mar 2023 01:57
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 4187

Re: PCS does not work

I did it several times, nothing new happened.
by zetor2000
23 Mar 2023 10:29
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 4187

Re: PCS does not work

I tried pcscopy several times. There was time, when the telephone was started, and there was time when telephone was not started.
The symptom is the same.
by zetor2000
22 Mar 2023 08:52
Forum: Passive Communication Server
Topic: PCS does not work
Replies: 7
Views: 4187

PCS does not work

Hi!

I have a site with PCS which does not work properly.
The PCS is a CS2 board. The software version is R100.1 n2.514-30, the same running in the call server.
I used netadmin -m to configure the PCS, it seems OK, there are hosts file entries, and i can use ping, telnet, ftp to or from the PCS. I ...
by zetor2000
31 Jul 2020 11:22
Forum: OmniVista 8770
Topic: Buffer overflow
Replies: 3
Views: 4711

Re: Buffer overflow

But we do not have real-time accounting enabled.
The PBX just drop some error messages, that appears several hours, 6 times. It is strange.
by zetor2000
24 Jul 2020 05:34
Forum: OmniVista 8770
Topic: Buffer overflow
Replies: 3
Views: 4711

Buffer overflow

Hi!
Recently we moved to R12, and we have a new 8770 with accounting.
Now i get some errors like: "ACCOUNTING: appli ACC_ETH feature incident 2 3" (information 275)
I looked after in incinfo, and it tells me this is a buffer overflow error, the capacity of the internal accounting buffer is exceeded ...
by zetor2000
29 May 2019 15:41
Forum: Beginner's questions about the Crystal Hardware
Topic: PSAL wiring guide
Replies: 3
Views: 7279

Re: PSAL wiring guide

Thank you, Vad!
I suppose the label shows 48V / 0V / PSAL, the polarity of the 48V is unknowwn. I do not remember. I have to check it, if i get back to my site. :)
I can only remember, if i made a wrong connection, my power sdupply's circuit breaker was shut down the power.

Go to advanced search