Search found 42 matches
- 18 Jul 2024 09:01
- Forum: OmniVista 8770
- Topic: license file on another server
- Replies: 6
- Views: 5613
Re: license file on another server
only one instance should running as stated ; shutdown one of them and perform a global synch and all will be back to normal in the next check
Thanks!
I am in a relatively new virtual environment, with several VMs, and there are 2 VMs which we use regularly. One is a file sharing machine, and ...
- 18 Jul 2024 02:07
- Forum: OmniVista 8770
- Topic: license file on another server
- Replies: 6
- Views: 5613
Re: license file on another server
Hi!
I have the same issue. My server is about to stop in 8 days.
https://i.kek.sh/sNq1vBtYhTm.png
I found the issue when i get back from vacation, and there were 11 days. I had another 8770 server instances on another machines, but i think there is only one instance running, but this server is ...
I have the same issue. My server is about to stop in 8 days.
https://i.kek.sh/sNq1vBtYhTm.png
I found the issue when i get back from vacation, and there were 11 days. I had another 8770 server instances on another machines, but i think there is only one instance running, but this server is ...
- 12 Oct 2023 02:23
- Forum: Other
- Topic: Full Ip abc network with 3 nodes
- Replies: 3
- Views: 4679
Re: Full Ip abc network with 3 nodes
In a home lab environment i suppose you neeed some extra hw stuff like common hw or WM cabinets, or voice hubs or similar thing you can put interface cards.
We used to make connections via LIOB boards, and BRA cards, but there was a limitation in the number of available channels.
In a home lab, you ...
We used to make connections via LIOB boards, and BRA cards, but there was a limitation in the number of available channels.
In a home lab, you ...
- 30 Mar 2023 04:57
- Forum: Passive Communication Server
- Topic: PCS does not work
- Replies: 7
- Views: 4187
Re: PCS does not work
Hi,
From the oxe do a copy of a database backup to the pcs using the following command
rcp /DHS3dyn/BACKUP/IMMED/mao swinst@pcs_ip_addr:/DHS3dyn/BACKUP/IMMED
Note: replace pcs_ip_addr with the ip address of the pcs
After coping the database, compare the file on the CS and on the PCS, to see if ...
- 28 Mar 2023 01:57
- Forum: Passive Communication Server
- Topic: PCS does not work
- Replies: 7
- Views: 4187
Re: PCS does not work
I did it several times, nothing new happened.
- 23 Mar 2023 10:29
- Forum: Passive Communication Server
- Topic: PCS does not work
- Replies: 7
- Views: 4187
Re: PCS does not work
I tried pcscopy several times. There was time, when the telephone was started, and there was time when telephone was not started.
The symptom is the same.
The symptom is the same.
- 22 Mar 2023 08:52
- Forum: Passive Communication Server
- Topic: PCS does not work
- Replies: 7
- Views: 4187
PCS does not work
Hi!
I have a site with PCS which does not work properly.
The PCS is a CS2 board. The software version is R100.1 n2.514-30, the same running in the call server.
I used netadmin -m to configure the PCS, it seems OK, there are hosts file entries, and i can use ping, telnet, ftp to or from the PCS. I ...
I have a site with PCS which does not work properly.
The PCS is a CS2 board. The software version is R100.1 n2.514-30, the same running in the call server.
I used netadmin -m to configure the PCS, it seems OK, there are hosts file entries, and i can use ping, telnet, ftp to or from the PCS. I ...
- 31 Jul 2020 11:22
- Forum: OmniVista 8770
- Topic: Buffer overflow
- Replies: 3
- Views: 4711
Re: Buffer overflow
But we do not have real-time accounting enabled.
The PBX just drop some error messages, that appears several hours, 6 times. It is strange.
The PBX just drop some error messages, that appears several hours, 6 times. It is strange.
- 24 Jul 2020 05:34
- Forum: OmniVista 8770
- Topic: Buffer overflow
- Replies: 3
- Views: 4711
Buffer overflow
Hi!
Recently we moved to R12, and we have a new 8770 with accounting.
Now i get some errors like: "ACCOUNTING: appli ACC_ETH feature incident 2 3" (information 275)
I looked after in incinfo, and it tells me this is a buffer overflow error, the capacity of the internal accounting buffer is exceeded ...
Recently we moved to R12, and we have a new 8770 with accounting.
Now i get some errors like: "ACCOUNTING: appli ACC_ETH feature incident 2 3" (information 275)
I looked after in incinfo, and it tells me this is a buffer overflow error, the capacity of the internal accounting buffer is exceeded ...
- 29 May 2019 15:41
- Forum: Beginner's questions about the Crystal Hardware
- Topic: PSAL wiring guide
- Replies: 3
- Views: 7279
Re: PSAL wiring guide
Thank you, Vad!
I suppose the label shows 48V / 0V / PSAL, the polarity of the 48V is unknowwn. I do not remember. I have to check it, if i get back to my site.
I can only remember, if i made a wrong connection, my power sdupply's circuit breaker was shut down the power.
I suppose the label shows 48V / 0V / PSAL, the polarity of the 48V is unknowwn. I do not remember. I have to check it, if i get back to my site.
I can only remember, if i made a wrong connection, my power sdupply's circuit breaker was shut down the power.