Search found 34 matches

by ainy
15 Dec 2015 07:05
Forum: SIP
Topic: SIP device call disconnect
Replies: 4
Views: 4424

Re: SIP device call disconnect

this happens when extension is configured as SIP device. Extensions which are configured as SIP extensions are working fine. So I think it can be a problem with SIP trunk group or some timer setting. if anyone has experienced this please share your resolution.
by ainy
15 Dec 2015 01:41
Forum: SIP
Topic: SIP device call disconnect
Replies: 4
Views: 4424

Re: SIP device call disconnect

hi, I have searched the forum could find anything that can help me on this issue. below is the motortrace file taken from a call made fromm extension 666 (SIP device) to 888 (IP 4038) traced started ... 1450161513 -> cl_daCalendar::dayOfWeek 1450161513 -> cl_daCalendar::dayOfWeek 1450161513 -> cl_da...
by ainy
14 Dec 2015 06:48
Forum: SIP
Topic: SIP device call disconnect
Replies: 4
Views: 4424

SIP device call disconnect

hi, I am connecting a grand stream phone GXV3275 on my oxe, which is in release 10.0. when configured the phone as SIP device incoming call are ok. but outgoing call get disconnect in 4 seconds after answering. in Trunk COS category 31 the default value for timer T313 is 40. and this is why call is ...
by ainy
09 Jun 2014 01:06
Forum: H323 / IP / Pimphony
Topic: Call transfer issue in SIP to analogue convertor
Replies: 3
Views: 3689

Re: Call transfer issue in SIP to analogue convertor

below is the mail from vendor (Zhone) Dears Please note that for starters, the Alcatel PBX is sending a "send only" INVITE to the zNID, and the zNID is responding back with a proper "receive only" 200 OK response. The Alcatel PBX rejects all upstream RTP from the zNID (as expecte...
by ainy
09 Jun 2014 00:58
Forum: H323 / IP / Pimphony
Topic: Call transfer issue in SIP to analogue convertor
Replies: 3
Views: 3689

Call transfer issue in SIP to analogue convertor

We have an issue with SIP to analogue convertor when used in OXO PABX system, The thing is that as per the attached figure 1 #ext 177(analogue phone connected to SIP to analogue convertor) dials #ext 176 (IP touch 4028), then #ext 176 answers the call and transfers the call to #ext 179(analogue phon...
by ainy
10 May 2014 04:31
Forum: My IC Phone
Topic: how to configure 8082 w/o 8770
Replies: 7
Views: 6618

Re: how to configure 8082 w/o 8770

My OXE system release is 10.0 and and i need to how to configure My IC without 8770 software. Any useful document?
by ainy
09 May 2014 07:17
Forum: My IC Phone
Topic: how to configure 8082 w/o 8770
Replies: 7
Views: 6618

Re: how to configure 8082 w/o 8770

do you have a doc to refer to know how to configure with out using 8770
by ainy
22 Apr 2014 15:20
Forum: My IC Phone
Topic: how to configure 8082 w/o 8770
Replies: 7
Views: 6618

how to configure 8082 w/o 8770

Hi,

can anyone guide me on how to configure My IC 8082 in oxe.
in my system i don't have 8770 license. Also share a document than can be of help.
by ainy
11 Dec 2011 23:32
Forum: Attendant
Topic: Wake up programe for guest room from 4068 Attendat
Replies: 2
Views: 3014

Wake up programe for guest room from 4068 Attendat

Hi,

I am not able to program wake up call to guest rooms using 4068 Attendant console.
when i dial wake up call prefix from attendant 4068 phone it display as unauthorized.

As there any thing that need to be done ....

Thanks in advance
by ainy
05 Oct 2011 03:25
Forum: SIP
Topic: Incoming FAX issue when sent in manual mode
Replies: 4
Views: 2706

Re: Incoming FAX issue when sent in manual mode

hi,

below are the details and attached is the 2 call scenarios with one successful and other not successful.

Calling number is 3320636 (External PSTN line)
Called number is 203 (DID number 3350203(PABX extension) )

Go to advanced search