How to save configuration on OS6360-P24

Post Reply
innovator
Member
Posts: 2
Joined: 07 Dec 2021 06:45

How to save configuration on OS6360-P24

Post by innovator »

Hello,
I have an Alcatel Lucent OS6360-P24 and i can't save the configuration.
If i try

Code: Select all

write memory
i get

Code: Select all

ERROR: Write memory is not permitted when switch is running in certified mode
The switch is new and i'm trying to setup some vlans, but i can't save my configuration.

Code: Select all

-> show system
System:
  Description:  Alcatel-Lucent Enterprise OS6360-P48 8.7.252.R02 GA, March 22, 2021.,
  Object ID:    1.3.6.1.4.1.6486.801.1.1.2.1.16.1.8,
  Up Time:      0 days 4 hours 36 minutes and 15 seconds,
  Contact:      Alcatel-Lucent Enterprise, https://www.al-enterprise.com,
  Name:         Test,
  Location:     Unknown,
  Services:     78,
  Date & Time:  MON JUL 12 2021 13:02:48 (UTC)
Flash Space:
    Primary CMM:
      Available (bytes):  734560256,
      Comments         :  None

Code: Select all

-> show running-directory

Mon Jul 12 13:04:18 : flashManager Main ALRT message:
+++ Virtual chassis configuration is NOT present in virtual chassis mode - inconsistent configuration

CONFIGURATION STATUS
  Running CMM              : MASTER-PRIMARY,
  CMM Mode                 : VIRTUAL-CHASSIS MONO CMM,
  Current CMM Slot         : CHASSIS-1 A,
  Running configuration    : CERTIFIED,
  Certify/Restore Status   : CERTIFY NEEDED
SYNCHRONIZATION STATUS
  Running Configuration    : NOT SYNCHRONIZED
Please help me, i'm new to Alcatel devices.
Thank you!
innovator
Member
Posts: 2
Joined: 07 Dec 2021 06:45

Re: How to save configuration on OS6360-P24

Post by innovator »

Problem solved by running

Code: Select all

reload from working no rollback-timeout
and then, i can run

Code: Select all

write memory
and

Code: Select all

copy running certified
Post Reply