Search found 74 matches

by slabr
10 Jan 2018 17:30
Forum: Users
Topic: Problem after deleting user
Replies: 8
Views: 6436

Re: Problem after deleting user

I don't have none of these boards. The system was on CPU 5_2 at the beginning and now is on HP appliances. I've deleted this entry and now everything is OK - I can use blocked MCDU as Network Number as I want to.

Thanks a lot for help.

Best regards
Slawek
by slabr
10 Jan 2018 14:13
Forum: Users
Topic: Problem after deleting user
Replies: 8
Views: 6436

Re: Problem after deleting user

OK, with cuser and /usr2/fab/tbl2obj.ref and /usr2/fab/obj2tbl.ref I've found, what is going on. There was in: DATA=>Data Application this: ┌─Consult/Modify: Data Application─────────────────────────────────────────────────────────┐ │ │ │ Node Number (reserved) : 1 │ │ Instance (reserved) : 1 │ │ Di...
by slabr
10 Jan 2018 13:02
Forum: Users
Topic: Problem after deleting user
Replies: 8
Views: 6436

Re: Problem after deleting user

OK, I understand. As I read about CUSER tool, is kind of command line SQL for MAO database which can do anything direct in database files (thats why should be use with caution). Is there any documentation about database structure and table relations? Where should I search for (which tables) for reso...
by slabr
10 Jan 2018 10:15
Forum: Users
Topic: Problem after deleting user
Replies: 8
Views: 6436

Re: Problem after deleting user

Nothing special: (1)oxe_a> checkdb Data base checking in progress ... /................ERROR 4351 : DATA INCONSISTENCY, Table ENTITY, entity=0 invalid cdt ERROR 4351 : DATA INCONSISTENCY, Table ENTITY, entity=3 invalid cdt ERROR 4351 : DATA INCONSISTENCY, Table ENTITY, entity=4 invalid cdt ERROR 435...
by slabr
10 Jan 2018 07:16
Forum: Users
Topic: Problem after deleting user
Replies: 8
Views: 6436

Problem after deleting user

Hello. I've got strange problem. OXE 9.1 system. After deleting one user (normal IP Touch 4068 station), the MCDU is not released. The deleted number from Station in Numbering Plan is changed to Data Application Call. Why this is happening and how this can be repaired? I've looked in incvisu and the...
by slabr
07 Oct 2016 06:54
Forum: Voicemail (46x5)
Topic: 4635 VPU5 will not boot
Replies: 9
Views: 5615

Re: 4635 VPU5 will not boot

OK, I got it. We've moved cabinets to standard rack from original Alcatel and not connect this wire. Do I need to have the green light which is in original rack or there is only need to connect brown wire to -48V?
by slabr
07 Oct 2016 03:57
Forum: Voicemail (46x5)
Topic: 4635 VPU5 will not boot
Replies: 9
Views: 5615

Re: 4635 VPU5 will not boot

Hi.

I've got the same problem. Can you please tell me what is PSAL cable and where it could be found?
by slabr
17 Jan 2013 14:04
Forum: Trunk Groups
Topic: Call transit to two different operators
Replies: 3
Views: 2590

Re: Call transit to two different operators

I've got everything configured for two operators (NPD, discriminators, etc.) and all is working correctly in both directions in OXE. But incoming number from CUCM will also be processed as from OXE? I mean, if I'd like to make outside call from CUCM through OXE, the outgoing number will be processed...
by slabr
16 Jan 2013 08:28
Forum: Trunk Groups
Topic: Call transit to two different operators
Replies: 3
Views: 2590

Call transit to two different operators

Hi all. I've got such a config: CUCM8.6<=T2-QSIG_ABC_F=>OXEr9.1<==>T2_ISDN_Operator1 \<==>T2_ISDN_Operator2 Can it be possible to transit calls from CUCM to both operators with different pool numbers? Unfortunatelly, Operator1 has one pool of DDIs and can show in setup only this pool and Operator2 h...
by slabr
16 Jan 2013 08:10
Forum: MAIN
Topic: Unexpected restart of all crystals during INT-IP2 link lost
Replies: 0
Views: 1180

Unexpected restart of all crystals during INT-IP2 link lost

Hi. I've got sytem r9.1 on duplicated Appliance Servers with crystal hardware. The system has two IO-IP links beetwen main crystal and Call Servers based on INT-IP2 cards and one INT-IP2 with compressors for IP Touch telephones. Everything works fine, but in last week the link to INT-IP2 card with c...

Go to advanced search