Search found 203 matches

by wallacezammit
01 Nov 2018 04:23
Forum: Trunk Groups
Topic: No Ringing Tone
Replies: 4
Views: 5302

Re: No Ringing Tone

There isn't a sip external gateway. There is a trunk group set as a Private Alcatel ABCF link using an INTIP3 board. This setup is used for communication between the Alcatel Enterprise and Alcatel AOCR server. I will check if there is the 'sdp in 18x' in this trunk group but I doubt it. Thanks and r...
by wallacezammit
23 Oct 2018 02:20
Forum: Trunk Groups
Topic: No Ringing Tone
Replies: 4
Views: 5302

No Ringing Tone

Hi, I have an OXE Rel 11.2.2 which is connected to an Alcatel-Lucent AOCR (Advice of Call Recording). The connection between OXE and AOCR is made through and INTIP3 setup as ABCF private. External Lines are ISDN PRA E1 30channels The system works as follows : 1) External incoming call is received by...
by wallacezammit
11 Dec 2017 05:02
Forum: Users
Topic: Overflow on Out of Service
Replies: 2
Views: 3517

Overflow on Out of Service

Hi, do you know if there is a way to tell the system (in general) to overflow to the attendant set for internal and external calls if a set is found to be out of service? I managed to overflow on Out of Service to the associate set of the extension number but I would like to know if I can make a gen...
by wallacezammit
11 Dec 2017 04:58
Forum: OmniVista 8770
Topic: Cannot take OXE Backup with 8770
Replies: 3
Views: 2797

Re: Cannot take OXE Backup with 8770

Therefore the 8770 must have the Configuration License for it to be able to take OXE backups?

Is it so?

Thanks and Regards
Wallace
by wallacezammit
30 Nov 2017 05:21
Forum: OmniVista 8770
Topic: Cannot take OXE Backup with 8770
Replies: 3
Views: 2797

Cannot take OXE Backup with 8770

Hi, I am trying to take a backup of OXE pabx from the 8770 by going into maintenance tab, selecting the mao and site specific operating system and job is failing with the following error 'maintenance account not available'. I am attaching a print screen of this. Do I need to create some account or i...
by wallacezammit
14 Nov 2016 07:47
Forum: SIP
Topic: Internal Sip Gateway Port Change
Replies: 2
Views: 2219

Re: Internal Sip Gateway Port Change

ok I will check with a new database then

Thanks
Wallace
by wallacezammit
08 Nov 2016 06:52
Forum: SIP
Topic: No Ringing Tone
Replies: 3
Views: 4848

Re: No Ringing Tone

Hi, Solved. The following are the changes I did: 1) External Lines - In ISDN Protocols Parameters tick 'simulate ringback tone for outgoing calls' 2) ARS GW parameters-> Protocol tab-> Enable the P-Early media for SIP Trunk. 3) System Misc-> Other labels-> SimulIpAlt Flag-> change the value to 01. R...
by wallacezammit
08 Nov 2016 04:16
Forum: SIP
Topic: Internal Sip Gateway Port Change
Replies: 2
Views: 2219

Internal Sip Gateway Port Change

Hi,

can the internal sip gateway port number (5060) be changed on oxe release 11.0.1?

Thanks and Regards
Wallace
by wallacezammit
08 Nov 2016 04:05
Forum: SIP
Topic: No Ringing Tone
Replies: 3
Views: 4848

Re: No Ringing Tone

Hi,

I will check and get back to you.

Thanks
Wallace
by wallacezammit
21 Oct 2016 04:12
Forum: SIP
Topic: No Ringing Tone
Replies: 3
Views: 4848

No Ringing Tone

Hi, I have the following scenario : An oxo with a SIP trunk. A common hardware oxe connected to the oxo by ISDN PRA back to back. The master is the oxe while the pra in the oxo is the slave. The oxe uses the PRA link to be able to use the SIP trunk in the oxo and make external calls. Outgoing calls ...